D. TSI Angle Error Sources and Behavior

Regardless of a TSI's angle resolution, accurate angle measurement results are only possible if instrument set up and pointing errors are minimized. Remember that in angle measurement three points are involved: a TSI location and two sighting locations. The two largest errors are instrument centering and pointing. And as with any other measurement type, the more measurements made the greater opportunity for random error cancellation leading to a more accurate result.