Differential leveling uses the vertical distance difference between two points to transfer an elevation from one point to another.

A summary of the process:

A Level is setup between two points, one whose elevation is known, Figure B-1.

 b 1
Figure B-1
Setting Up

 

A backsight (BS) reading is taken on the known point, Figure B-2, using a rod divided into feet (or meters) and subdivisions thereof. This determines how far above the LoS is above the known point. Adding the BS reading to the point elevation gives the elevation of the instrument (EI, aka, Height of the Instrument, HI).

b 2
Figure B-2
Backsight Reading

 

A foresight (FS) reading is taken on the unknown point, Figure B-3, to determine how far above it the LoS is. Subtracting the FS reading from the instrument elevation gives the point elevation.

 b 3
Figure B-3
Foresight Reading

 

The elevation of B is determined by adding the difference between the BS and FS readings:

ElevB = ElevRed+(BSRed-FSB)

The instrument is moved to a position between B and the next point and the process repeated.


2. Equipment

The equipment list for differential leveling minimally includes:

  • Level instrument
  • Tripod
  • Level rod

Although not always needed, a rod bubble and turning pin or turtle are often included.

a. Level Instrument

A level instrument is a telescope mounted so that it can be oriented horizontally. The traditional Dumpy Level, Figure B-4, is a relatively simple rendition of a level. It consists of a telescope with an attached bubble vial on a rotating head supported by four leveling screws.

 b 4
Figure B-4
Dumpy Level


The most common modern instrument is an Automatic Level. It gets its name from an internal compensation system which automatically maintains a horizontal LoS if the instrument is disturbed. The compensation system uses a combinations of fixed and free swinging prisms and mirrors. When the instrument is tilted the compensation system reacts to maintain a horizontal sight line at the observer’s end. The stylized cross-sectional views in Figure B-5 shows how the incoming horizontal LoS is reflected and refracted and emerges at the eyepiece in a parallel path.

b 5
Figure B-5
Compensator Reacting

 

The instrument is leveled using a circular bubble. The etched circle on the bubble glass is a general indicator of the compensator's operating range. If the bubble is outside the circle, the compensator may be at its physical limit and unable to maintain a horizontal LoS.

b. Tripod

A tripod is a three-legged support platform for the level, Figure B-6. The tripod's primary material can be wood, metal, fiberglass, or plastic; its legs fixed length or extendable. It usually has a flat top and a mounting screw for instrument attachment. The tripod’s function is to ensure a stable instrument setup for reliable measurements.

b 6
Figure B-6
Tripod


c. Level Rod

A level rod is a tall linear measuring scale. In English units, the divisions may be feet and decimal feet or feet-inches and fractional inches. Feet and decimal feet are most commonly used. In the metric system the divisions are meters and decimal meters.

The rod can be constructed of wood, metal, or fiberglass. Most rods telescope or extend in order to allow large elevation difference determinations yet collapse into a compact form.

There are many width and gradation styles depending on application. The most universal design is the Philadelphia rod, a portion of which is shown in Figure B-7.

 

 b 7

 

 

Red numbers are the full foot readings.

Black numbers are the 0.1 ft readings

The bars are each 0.01 ft tall and spaced 0.01 ft apart.

Peaks on the bars correspond to the adjacent 0.1 or foot reading.

A peak without an adjacent number corresponds to a half-tenth or 0.05 ft.

At distances up to about 300 feet, a Philadelphia rod can be read directly to 0.01 ft. 

Figure B-7
Level Rod
 

 Reading a rod consists of identifying the full foot and tenth foot, then counting up or down to determine the hundredth foot.

Figure B-8 shows some example rod readings.

 b 8
Figure B-8
Example Rod Readings

 

The reading must be made with the rod held vertically to correctly determine instrument height above a point. There are a few ways to ensure the rod is vertical when the reading is made.

One method is to use a rod bubble, Figure B-9. This is a circular bubble which is held against or mounted to a level rod. The rod is vertical when the bubble is centered.

 b 9
Figure B-9
Rod Bubble

 

 If a rod bubble is not available, then the rod can be waved, or rocked, slowly back and forth, Figure B-10.

The instrument operator will see the rod reading increase and decrease as the rod is waved. The reading is too high when the rod is tilted forward or backward. It is lowest when the rod is vertical. The operator records that reading. 

b 10
Figure B-10
Waving the Rod

 

 d. Turning point

Often when running a level line the distances between points may be too long for reliable reading or there may be obstructions. In such cases intermediate temporary points are established and leveled through. If a suitable stable point is not available then a turning point is used.

A turning point is usually a steel pin with a rounded top which can be firmly pounded into the ground, Figure B-11. It is left in position until after a BS reading is taken on it and the next elevation point established. Only then is it safe to remove the pin since its elevation is no longer needed.

Where the surface is hard, making it difficult to pound in a pin, a turtle can be used instead. A turtle is a heavy triangular or circular steel plate with three short equally spaced legs and a short rounded pin at top center, Figure B-12. When placed, the weight of the turtle helps keep it relatively stable wile readings are taken. On some surfaces, dropping the turtle helps seat its legs more firmly providing additional stability.

 b 11              b 12
Figure B-11
Turning Point
      Fgure B-12
Turtle

 

 